Building Deficiencies Summary:

Breakdown by building of specific facility deficiencies as identified by OSFC and Lesko Architecture reports

FACILITY

Bassett – Built 1967

Dover– Built 1949

Hilliard– Built 1954

Holly Lane– Built 1961

Heating

Temp. controls-poor

No energy recovery

Temp. controls-poor

No energy recovery

Temp. controls-poor

No energy recovery

Temp. controls-poor

No energy recovery

Roofing

1967, 1987, 1990-poor

Poor

Fair-past expected life

OK

Ventilation/

Exhaust

Fair/poor-below code

Fair/poor- below code

Fair/poor- below code

Fair- below code

Electrical

Wiring-fair/poor

Distrib. equipment-fair/poor

Main switch-poor; Switchgear-fair

No surge suppression

Main panels-fair

No surge suppression

Frequent breaker tripping in panels

Distribution system/wiring-poor

No surge suppression

Plumbing/

Fixtures

Supply pipes-fair

Backflow-fair

Kitchen fixtures-poor

Supply pipes-fair

Backflow-fair

Kitchen fixtures-fair

Supply pipes-fair

Backflow-fair

Kitchen fixtures-fair

Backflow-fair

Supply pipes-fair

Waste pipes-poor

Windows

1967-fair/poor, 1987-fair

Curtainwall/glass block-fair

Fair-replace original window

Fair-Replace storefront/curtainwall

Foundation

Continuing settling

OK

Canopy columns-poor

Minor cracks above grade

Walls/ Chimney

Veneer separating–poor

Exterior wall separating

West walls & 1 chimney-poor

Masonry-joints-fair/poor

Serious erosion of joints in sills and lower courses of brickwork, allowing moisture intrusion

Curtainwall separated from masonry in NW corner of library-poor

Extensive structural steel rust

Minor cracks and spalling

Floors/Roof

1987 slab floors rising-poor

2nd story floor-cracked S. wing

Roof at canopy W. entrance-poor

Steel floor gratings-poor

Roof deck S. gym wall-sagging

Concrete roof over gym deteriorating

Steel roof deck near load capacity

General Finishes

Floors-good to poor

Walls-good to fair

Floors-good to poor

Kitchen equip.-poor

Some floor tiles with asbestos

Door frames/doors-original, fair

Classroom finishes-fair/poor

Kitchen equipment-fair/poor

Some vinyl asbestos tile floors

Kitchen equipment-poor

Toilet Partitions-Fair

Interior Lighting

Well below code -fair/poor

Energy inefficient

Well below code-fair/poor

Energy inefficient

Well below code -fair/poor

Energy inefficient

Well below code–fair/poor

Energy inefficient

Emerg/Exit Lighting

Below code-Fair/Poor

Below code-fair/poor

Below code-fair/poor

Inadequate exterior lighting

Below code-fair/poor

Inadequate exterior lighting

Fire Alarm

Add strobes

Add strobes

Consolidate dual systems

Add strobes

Add strobes

Add magnetic hold-open devices on corridor doors

Handicap Access

Not ADA compliant-fair

Door hardware, signage, exits, areas of refuge, drinking fountains, toilet facilities-not ADA compliant

No lift for stage; door hardware, signage, entrance, drinking fountains, toilet facilities-not ADA compliant

No lift for stage; door hardware, signage, entrance assist, drinking fountains, toilet facilities-not ADA compliant

Site Condition

Asphalt pavement-poor

Concrete curb-poor

Front asphalt pavement-poor

Concrete curbs-good/fair

Asphalt paving-fair/poor

Lack of curbs

Play area/entrance drive asphalt–poor

Asphalt-good/fair in other locations

Curbs-fair/poor-severe erosion

Exterior Doors

1967/1987 doors-fair

Fair/Poor

Poor

Steel doors lack weather stripping

Interior vestibule doors-poor

Life Safety

No emergency generator

No fire suppression system

No fire suppression system

No emergency generator

Stairs/guardrails/walls not code compliant

No fire suppression system

No emergency generator

No fire suppression system

No emergency generator

Technology

Paging system-fair/poor

Av system-fair-below code

Sound system-fair/poor

Paging system-fair

Sound system/clocks-fair/poor

AV-fair- below code

Paging system-fair

AV-Fair- below code

Sound system-fair/poor

Paging system-fair

Sound system/clocks-fair

AV-Fair- below code

 

 

 

FACILITY

Parkside– Built 1966

LBMS– Built 1970

WHS– Built 1960

Heating

Rooftop equipment-fair

Temp controls-poor

No energy recovery

Temp controls-poor

No heat in Lobby

No energy recovery

Heating system/hot water boilers-poor

Temp controls-poor

No energy recovery

Roofing

Fair-ponding on flat roof; some original roof

Roof/insulation-fair/poor- gym, science leaks

Roof-fair/poor

Ventilation/Exhaust

Fair -below code; controls-poor

Exhaust-poor

AH Units-Fair

Ventilation-below code

Exhaust-Fair

Ventilation-fair-below code

Exhaust-Good

Electrical

Wiring- poor

Distribution equipment- poor

No surge suppression; breakers tripping

Main panel-no surge suppression

Original panels-nearing life expectancy

Main electrical room full

Main electrical room full

Main panel-no surge suppression

Original panels-past life expectancy

Replace rooftop conduit per Fire Dept.

Plumbing/

Fixtures

Supply pipes-fair

Backflow-fair

Waste pipes-poor

Kitchen fixtures-poor

Backflow-fair

Supply pipes-fair

Wall/floor mounted fixtures-fair/poor

Backflow/supply pipes/waste pipes-fair

Damaged drains, no locker room hot water

Water main-poor; kitchen fixtures/restrooms-fair/poor

No hot water recirculation system

Windows

Curtainwall-fair/poor

Seals failing in windows prior to 1998-Poor

Courtyard window-wall leaks

No required integral blinds

Windows/storefront/curtainwall prior to 1970-fair/poor

Foundation

S. Wall of Gym Movement

OK

OK

Walls/ Chimney

Cracks in masonry-gym walls

Chimney-fair/poor

OK

Precast soffit at main entrance separating

Brick stains and spalling; open cracks at addition junctions

Interior concrete/tile masonry cracks

Floors/Roof

Gym floor sinking

OK

1970 Concrete/metal deck deteriorating

1960 East Wing floors sinking

General Finishes

Toilet partitions, kitchen equipment, 1966 lockers, operable walls – Poor

Floors-fair (buckling tile & gym floor)

Lockers/gym bleachers/toilet partitions-poor

Kitchen-2nd serving line required

Acoustic ceiling/operable partitions-fair/poor

Gym floor/kitchen floor-Poor

Casework-fair/poor

Interior Lighting

Lighting/controls well below code -Fair/Poor

Energy Inefficient

Lighting/controls well below code-Fair/poor

Energy Inefficient

Lighting/controls well below code-Fair/poor

Energy Inefficient

Emerg/Exit Lighting

Emergency lighting below code-Fair/Poor

Exit lighting & signs-Poor

Emergency lighting below code-Fair/poor

Exit lighting & signs-Poor

Emergency lighting below code-Fair/poor

Exit lighting & signs-Poor

Fire Alarm

Add strobes

Add strobes

Add strobes

Handicap Access

Signage, toilets, stage lift, door assist, door hardware, counters not ADA compliant-Fair/Poor

Gym mezzanine/locker rooms inaccessible

doors, signage not ADA compliant

Most signage, drinking fountains, hardware, toilet fixtures, music risers, partitions non-compliant-Poor

Site Condition

Asphalt pavement-fair/poor

Site needs drainage and regrading at gym

Asphalt & Curbs NE parking lot/drive-Poor

No exit walks on N and W sides of building

Asphalt pavement-Fair/poor

Concrete walks-25% Poor

Exter. Doors

1966 steel doors/aluminum doors-poor

OK

Doors prior to 1989-Poor

Life Safety

No fire suppression system

No emergency generator

No fire suppression system

No Emergency Generator

No fire suppression system

Handrails/guardrails below code

Generator old and undersized

Technology

Paging system-fair

Av system-fair-below code

Clocks/sound system-fair/poor

Paging System-Poor

AV System-Fair-below code

Clocks/Sound System- Poor

Paging System-Poor

AV system-fair-below code

Clocks/sound system - Poor